By default, inductionloops have zero length and only a car at a time can occupy it. If you set the length attribute, then multiple cars may occupy the inductionloop and the occupancies above 100% reflect this. Occupancy above 100% may also happen with zeo-length loops in sublane simulation with multiple vehicles driving in parallel on the same lane. The documentation now reflects this.
Am Mi., 2. Nov. 2022 um 09:44 Uhr schrieb till.wenke < [email protected]>: > Hi folks, > > ... and another questions about the values that induction loops provide. > There is occupancy which should be the percentage of the time a car is on > the loop (so 0 to 100 %) nevertheless I am getting values above 100 (this > time via traci and in the output xml-file). Generally speaking the longer > the loop the more off are the values so for short loops it can happen to > get 200% and for long ones 700 %. > > Can anybody help me with this and clarify it? > > > Cheers > > Till > > _______________________________________________ > sumo-user mailing list > [email protected] > To unsubscribe from this list, visit > https://www.eclipse.org/mailman/listinfo/sumo-user >
_______________________________________________ sumo-user mailing list [email protected] To unsubscribe from this list, visit https://www.eclipse.org/mailman/listinfo/sumo-user