By default, inductionloops have zero length and only a car at a time can
occupy it.
If you set the length attribute, then multiple cars may occupy the
inductionloop and the occupancies above 100% reflect this.
Occupancy above 100% may also happen with zeo-length loops in sublane
simulation with multiple vehicles driving in parallel on the same lane.
The documentation now reflects this.

Am Mi., 2. Nov. 2022 um 09:44 Uhr schrieb till.wenke <
[email protected]>:

> Hi folks,
>
> ... and another questions about the values that induction loops provide.
> There is occupancy which should be the percentage of the time a car is on
> the loop (so 0 to 100 %) nevertheless I am getting values above 100 (this
> time via traci and in the output xml-file). Generally speaking the longer
> the loop the more off are the values so for short loops it can happen to
> get 200% and for long ones 700 %.
>
> Can anybody help me with this and clarify it?
>
>
> Cheers
>
> Till
>
> _______________________________________________
> sumo-user mailing list
> [email protected]
> To unsubscribe from this list, visit
> https://www.eclipse.org/mailman/listinfo/sumo-user
>
_______________________________________________
sumo-user mailing list
[email protected]
To unsubscribe from this list, visit 
https://www.eclipse.org/mailman/listinfo/sumo-user