Hello everyone, I am trying to manipulate traffic light systems via TraCI (in VEINS). Changing (reducing) the remaining duration of the current phase via TraCI (command 0x24) works well for static traffic lights. However, when changed to actuated traffic lights it does not seem to work any longer. I already reduced minDur of the phase to be less then the reduced duration set by TraCI. So that should not be the problem.
When queried about the assumed time of next switch (command 0x2d) via TraCI, the value i wish to set is returned. But in the simulation it is still ignored. Is the command ignored for actuated traffic lights or am i missing something? All examples I found for setting the duration only use static traffic light definitions. Kind Regards, Dominik Buse ------------------------------------------------------------------------------ _______________________________________________ sumo-user mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/sumo-user