Hello,
this is a bug (http://sumo.dlr.de/trac.wsgi/ticket/2701). Thanks for
reporting.
As a workaround you can keep the tls file outside the .net.xml and just add
it a simulation time.
regards,
Jakob

2016-11-25 13:46 GMT+01:00 Joerg Schweizer <joerg.schwei...@unibo.it>:

> Dear all,
> I tried to simulate actuated traffic lights,
> but my min max duration definitions have been eliminated when
> netconverting the tll file. This means, the net file did not contain the
> minDur, maxDur attributes.
>
> Is there anything I have overlooked?
>
> I have attached the all files to build the network with:
>
> netconvert --verbose --ignore-errors.edge-type --node-files
> square3_trips.nod.xml --edge-files  square3_trips.edg.xml
> --connection-files  square3_trips.con.xml --output-file
> square3_trips.net.xml --tllogic-files  square3_trips.tll.xml
>
> only node id="1/1" has an actuated traffic light.
>
> Thanks,
> Joerg
>
> ------------------------------------------------------------
> ------------------
>
> _______________________________________________
> sumo-user mailing list
> sumo-user@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/sumo-user
>
>
------------------------------------------------------------------------------
_______________________________________________
sumo-user mailing list
sumo-user@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/sumo-user

Reply via email to