Hello, this is a bug (http://sumo.dlr.de/trac.wsgi/ticket/2701). Thanks for reporting. As a workaround you can keep the tls file outside the .net.xml and just add it a simulation time. regards, Jakob
2016-11-25 13:46 GMT+01:00 Joerg Schweizer <joerg.schwei...@unibo.it>: > Dear all, > I tried to simulate actuated traffic lights, > but my min max duration definitions have been eliminated when > netconverting the tll file. This means, the net file did not contain the > minDur, maxDur attributes. > > Is there anything I have overlooked? > > I have attached the all files to build the network with: > > netconvert --verbose --ignore-errors.edge-type --node-files > square3_trips.nod.xml --edge-files square3_trips.edg.xml > --connection-files square3_trips.con.xml --output-file > square3_trips.net.xml --tllogic-files square3_trips.tll.xml > > only node id="1/1" has an actuated traffic light. > > Thanks, > Joerg > > ------------------------------------------------------------ > ------------------ > > _______________________________________________ > sumo-user mailing list > sumo-user@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/sumo-user > > ------------------------------------------------------------------------------ _______________________________________________ sumo-user mailing list sumo-user@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sumo-user