On 4/4/06, {Darkavich} <[EMAIL PROTECTED]> wrote:
> On Apr 4, 2006, at 7:19 AM, Kevin wrote:
>> i'm trying to configure Active/Standby failover with IPMP.
>> however i'm worry about virtual interface,
>> is it possable to use virtual interface for SunRay conneting ??

Sun Ray tries very hard to ignore virtual interfaces.  IPMP can
work, but it only works properly if you arrange to use "physical"
interfaces for data transfer and use virtual interfaces for IPMP
test addresses.

> I am using this with no problem. Here is my configuration:
>
>
> sr-san-19:smisrack [103]egrep sr-san-19 /etc/hosts
> 10.43.12.92     sr-san-19-bge0 sr-san-19-pri
> 10.43.12.93     sr-san-19-bge1 sr-san-19-sec
> 10.43.12.91     sr-san-19
>
>
> sr-san-19:smisrack [105]egrep sr-san-19 /etc/hostname.bge?
> /etc/hostname.bge0:sr-san-19-bge0 netmask + broadcast + -failover deprecated 
> up group qualnet addif sr-san-19 netmask + broadcast + failover up
> /etc/hostname.bge1:sr-san-19-bge1 netmask + broadcast + -failover deprecated 
> standby up group qualnet

On a standalone server this configuration can work, more or less
by accident.

In a failover group it could appear to work but it wouldn't really be
working in the way in which you intended.  It would appear to work
only because of a bug (6399233) and when that bug gets fixed this
configuration will fail.

If IPMP in a failover group is important to you then you should open
a support call against RFE 6405408 and get its priority increased.

OttoM.
__
ottomeister

Disclaimer: These are my opinions.  I do not speak for my employer.
_______________________________________________
SunRay-Users mailing list
[email protected]
http://www.filibeto.org/mailman/listinfo/sunray-users