Flow control settings made no difference for me.
I have tried that.
Ivar
John Francis wrote:
2009/10/8 Wouter Coppens <[email protected]>:
Hi,
Is there anything like the hires_tick for Linux?
Just turn flow-control on on your switch. Most smart/managed switches
have this feature.
Thanks,
Wouter
________________________________
From: Ivar Janmaat [mailto:[email protected]]
To: SunRay-Users mailing list [mailto:[email protected]]
Sent: Wed, 07 Oct 2009 22:30:01 +0200
Subject: Re: [SunRay-Users] Gigabit Sun Ray switches revisited (stripes and
hanging networkinterfaces)
Hello Rich,
The set hires_tick works!
I can use the 1Gbit again wihout the striping.
Thank you very much!
Ivar
Rich Teer wrote:
I never mess with (i.e., disable) the auto-negotiate settings. That way
lies bad ju-ju... Just set the hi_res clock in /etc/system and rely on
autonegotiation, and it'll be fine.