Hi Karl, Bob; We too are trying to globally disable poweroff on the new sunray 3 devices. We went/wanted to use the params file, but didn't see a poweroff= parameter in the utfwadm man page. Is this feature actually supported?
Thanks, Devin -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Karl Rossing Sent: Tuesday, January 11, 2011 5:03 PM To: Bob Doolittle Cc: SunRay-Users mailing list Subject: Re: [SunRay-Users] options to disable power-off function for sunray3 On 11-01-11 5:19 PM, Bob Doolittle wrote: > On 01/11/11 17:30, Karl Rossing wrote: >> On 10-08-13 9:18 AM, Jörg Barfurth wrote: >>> Jörg Barfurth schrieb: >>>> [email protected] schrieb: >>>>> I want to disable power off on sunray3. >>>>> >>>> [...] >>>> The following should work for you: >>>> >>>> # cat > /tftpboot/SunRayP9.parms << EOF >>>> version=_NONE_ >>>> poweroff=0 >>>> EOF >>>> # chmod +r /tftpboot/SunRayP9.parms >>>> >>> Just to be clear: the "poweroff" parms key controls the automatic >>> poweroff of the Sun Ray unit after a certain time of non-use. >> >> My parms file looks like >> more SunRayP9.parms >> version=4.2_140993-06_2010.10.08.21.53 >> revision=0 >> poweroff=0 >> barrier=422 >> >> But for some reason, the DTU's still power off. >> >> Do i need to rerun utfwsync after I change the parms file? > > You shouldn't have to, if they're powering down. When they come up > they should pick up the proper firmware version and parms. > What does utfwload -a report? Are the DTUs running the version of > firmware you expect? > > -Bob > Yes "4.2_140993-06_2010.10.08.21.53" utquery shows poweroff=30 I then did an utfwsync and utquery still shows poweroff=30 Karl CONFIDENTIALITY NOTICE: This communication (including all attachments) is confidential and is intended for the use of the named addressee(s) only and may contain information that is private, confidential, privileged, and exempt from disclosure under law. All rights to privilege are expressly claimed and reserved and are not waived. Any use, dissemination, distribution, copying or disclosure of this message and any attachments, in whole or in part, by anyone other than the intended recipient(s) is strictly prohibited. If you have received this communication in error, please notify the sender immediately, delete this communication from all data storage devices and destroy all hard copies. _______________________________________________ SunRay-Users mailing list [email protected] http://www.filibeto.org/mailman/listinfo/sunray-users _______________________________________________ SunRay-Users mailing list [email protected] http://www.filibeto.org/mailman/listinfo/sunray-users