Can you clarify what you mean by port mapper? Are you talking about follow me printing?

On 9/27/11 6:43 AM, Paul Whitener wrote:
Thanks Peter!  I will check it out!

On Tue, Sep 27, 2011 at 8:31 AM, Peter Åstrand <[email protected]
<mailto:[email protected]>> wrote:


        I have a RHEL5 server with 4GB ram running SRSS 5.1.  We have
        about 10 users across 15 DTUs.    We "were" using uttsc to
        connect to a remote (states
        away) Win2008R2 termserver that once logged in pushes a single
        app.  We
        found that when a user pulled their card to move to another DTU, the
        portmapper in RHEL5 changed the printer ports from the original
        session used to new ports.  This caused printers not to redirect
        to the new session
        correctly and caused all kind of print fun for the users!  If
        they did
        redirect, the "printer number" changed and the this confused the
        users.

        So we moved to using RHEL5's rdesktop implementation.  It does
        not seem to
        have issues with the mapper and the session and printers stay
        statefull.
        Printers work great.  However, as DTU usage has increased with
        students in
        full session, we are seeing lockups on the DTUs.  The lockups
        seem to be
        random.  We can not pin it to any one operation done on the
        Win2008R2
        server.  Interestingly enough, if the user goes to a laptop and
        pulls the
        rdesktop session to  it, the session unfreezes and they can
        work.  They then pull it back to the DTUs and continue.


    Are you running rdesktop in full screen mode, or in a window? RHEL5
    ships with rdesktop 1.6.0, which does not work very well with 2008
    R2. I suggest that you try rdesktop 1.7.0 instead. If the problem
    persists, try a "strace" on the rdesktop process. That should give you
    a clue about what's going on.

    Best regards, ---
    Peter Åstrand           ThinLinc Chief Developer
    Cendio AB http://www.cendio.com
    Wallenbergs gata 4
    583 30 Linköping        Phone: +46-13-21 46 00
    <tel:%2B46-13-21%2046%2000>




_______________________________________________
SunRay-Users mailing list
[email protected]
http://www.filibeto.org/mailman/listinfo/sunray-users
_______________________________________________
SunRay-Users mailing list
[email protected]
http://www.filibeto.org/mailman/listinfo/sunray-users

Reply via email to