Oleg, Yes the log shows that the sensors were never triggered, but I would rather zero out the TRIG_CONDITION parameter. The code I'm testing now distinguishes between Eyesis mode and other 10359 applications and program default /etc/autocampars.xml accordingly. For Eyesis camera will use hardware inter-camera synchronization by default, other 10359 applications - internal trigger (TRIG=4, TRIG_CONDITION=0), 353 without the 10359 board will default to TRIG=0. In most multi-sensor setups (but the simple one where 10359 is used just as a multiplexor to switch between different sensors (i,e, day/night) the sensors should run synchronized. And the current code is built around it, it needs TRIG=4 mode,
Andrey
_______________________________________________ Support-list mailing list Support-list@support.elphel.com http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com