Hallo Heinrich, The log shows that you have 10359 multiplexor board, the problem may be related to either bad contact in one of the 4 connectors (2 on the cable ends between the sensor and the 10359 and 2 - on the cable between the 10359 and 10353 boards) or the wrong phase settings for either main (10353) or the multiplexor (10359) board.
Did you receive the camera fully assembled or you connected some of the boards yourself? What are the cable lengths (10353 - 10359) and (10359 - 10338) ? Did the camera work initially and images got corrupted later? Did you always use 10359 board or you tried just the 10353+10338 ? We'll try to reproduce the same result or suggest more tests. It is OK to attach small files/compressed logs, but the mailing list software blocks large files, like the full size image, you can either post them somewhere or just attach to an email to elphel - we'll post it ourselves. Andrey
_______________________________________________ Support-list mailing list [email protected] http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com