Richard, These are custom cables with ground lines shielding data lines and 
wide power lines, and their width is lower than regular cables so it is easier 
to route them too. I would definitely recommend them for production systems. 
For quick experiments you may use just regular flex jumpers (Digi-Key, Mouser) 
with 0.5mm pitch, 30 contacts, t=0.3mm, same side contacts, gold plating (for 
testing you may use regular tin plating, I would not recommend to use them in 
the sewer environment. Andrey ---- On Thu, 15 Nov 2018 16:35:01 -0800 Richard 
Rigby <rri...@redzone.com> wrote ---- Hi Andrey, Are these cables custom, or 
can we order them from another supplier? Kind regards, Richard Rigby Software 
Developer www.redzone.com  Ph: +64 9 479 9901 Fax: +64 9 479 9904 13 Tarndale 
Grove • Albany • Auckland 0632 • New Zealand On Fri, 16 Nov 2018 at 12:26, 
Elphel Support <support-list@support.elphel.com> wrote: 
_______________________________________________ Support-list mailing list 
Support-list@support.elphel.com 
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com 
Richard, We have many of only 70mm and 250mm, the other lengths shown here 
https://wiki.elphel.com/wiki/File:Elphel_cables.jpeg are in just sample 
quantities ~5, but we can reorder them if needed. Andrey ---- On Thu, 15 Nov 
2018 15:17:09 -0800 Richard Rigby <rri...@redzone.com> wrote ---- Hi Andrey, At 
least 100mm up to 130mm. The cable we have at the moment are 70mm. Kind 
regards, Richard Rigby Software Developer www.redzone.com  Ph: +64 9 479 9901 
Fax: +64 9 479 9904 13 Tarndale Grove • Albany • Auckland 0632 • New Zealand On 
Fri, 16 Nov 2018 at 12:15, Elphel Support <support-list@support.elphel.com> 
wrote: _______________________________________________ Support-list mailing 
list Support-list@support.elphel.com 
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com 
Richard, What length of the cables do you need? Andrey ---- On Thu, 15 Nov 2018 
15:10:32 -0800 Richard Rigby <rri...@redzone.com> wrote ---- Hi Oleg, I would 
like to purchase some of the flex cables used to connect to the sensors. Could 
you please provide my with the specs/details required for purchasing? Thank 
you. Kind regards, Richard Rigby Software Developer www.redzone.com  Ph: +64 9 
479 9901 Fax: +64 9 479 9904 13 Tarndale Grove • Albany • Auckland 0632 • New 
Zealand _______________________________________________ Support-list mailing 
list Support-list@support.elphel.com 
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com
_______________________________________________
Support-list mailing list
Support-list@support.elphel.com
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com

Reply via email to