-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Somebody in the thread at some point said:
| @Andy, here some outputs: | | [EMAIL PROTECTED]:~# | cat /sys/devices/platform/bq27000-battery.0/power_supply/bat/current_now | cat: read error: Timer expired Something's broken somewhere... there have been issues with HDQ communication timing but that's only on 2.6.26+ branches IIRC. The obvious thing to do would be swap out with another CC battery and see if the problem belongs to that battery or the Freerunner, but I guess you only have the one battery. Timeout error as shown typically means either the battery HDQ pin is not connected, but it can mean other things like our timing is wrong talking to it, pin on CPU is dead, etc. - -Andy -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.4.9 (GNU/Linux) Comment: Using GnuPG with Fedora - http://enigmail.mozdev.org iEYEARECAAYFAkjZ4zAACgkQOjLpvpq7dMpeUQCfcrZl+BNl2TF+qRHKtI28E7Mg NuwAnA3ZCKw80pNJIa2FxWvAreFUnVqG =bK6j -----END PGP SIGNATURE----- _______________________________________________ support mailing list [email protected] https://lists.openmoko.org/mailman/listinfo/support