No, it's actually automatic on both sides.

But would it be the reason for the CPU to raise this high?

Should I input a higher value in kthreads of em driver?


Chris Buechler wrote:

On Wed, Jul 29, 2009 at 12:54 PM, Lenny<[email protected]> wrote:
Just like I answered previously, without the pfSense Alteon was able to
handle the load without problems.

Cisco switch also didn't have any errors on the interface. Plus, I only
started to see errors, when the high load began and at that same time I also
saw some packet loss on the firewall.

It sounds like you have a duplex mismatch potentially. Are you hard
coding one end or the other and not both?

---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]
For additional commands, e-mail: [email protected]

Commercial support available - https://portal.pfsense.org


Reply via email to