On 2014-03-17, [email protected] wrote:

I don't believe that most Betmax systems had the ability to lock to standard SMPTE time code.

In that case the path of least resistance probably would have been to slave the word clock of one converter to that of another, and put in an alignment pulse. That way the converters would stay phase coherent despite clock skew, and you could achieve perfect alignment later on using the calibration signal.

Of course unless the F1 was expressly designed to accept an external clock, that would mean touching the internals of a still rather expensive unit...
--
Sampo Syreeni, aka decoy - [email protected], http://decoy.iki.fi/front
+358-40-3255353, 025E D175 ABE5 027C 9494 EEB0 E090 8BA9 0509 85C2
_______________________________________________
Sursound mailing list
[email protected]
https://mail.music.vt.edu/mailman/listinfo/sursound