On Mon, 21 Jun 1999 14:16:02, Pete Rickard <[EMAIL PROTECTED]> said:
>
> Another related question:  How to interface the HP-IB (GP-IB) parallel
> connectors with RS-232 signals on a D25 cable?  I have a circa-1986
> HP 9000 "host" computer (up to 8users easily via the MUX, which are
> serial DB25's for "dumb" terminals).  But it'd be nice to use PARALLEL
> (or Centronics-type) printers, etc. with the HP-version GP-IB's.
>
Pete -

The easiest way is to go to www.blackbox.com (IIRC) and check out their IEEE-
488 converters. I've used them for IEEE-488 <-> RS-232, and had good
success. (I was working on HP-1000 series systems back in the late 70s and
80s) I _believe_ they have an inexpensive adapter that will allow you to run
a Centronics parallel printer from an HP-IB.

Dave