Author: mjordan
Date: Sat Dec  6 12:15:20 2014
New Revision: 429031

URL: http://svnview.digium.com/svn/asterisk?view=rev&rev=429031
Log:
res/res_monitor: Reset in/out sample counts on Monitor start

When repeatedly starting/stopping a Monitor on a channel, the accumulated
in/out sample counts are never reset to 0. This can cause inadvertent jumps
in the recordings, as the code in the channel core will determine incorrectly
that a jump in the recorded file position should occur. Setting the sample
counts to 0 simply reflects the initial state a Monitor should be in when it
is started, as this is the initial count that would be on the channels at that
time.

ASTERISK-24573 #close
Reported by: Nuno Borges
patches:
  24573.patch uploaded by Nuno Borges (License 6116)

Modified:
    branches/11/res/res_monitor.c

Modified: branches/11/res/res_monitor.c
URL: 
http://svnview.digium.com/svn/asterisk/branches/11/res/res_monitor.c?view=diff&rev=429031&r1=429030&r2=429031
==============================================================================
--- branches/11/res/res_monitor.c (original)
+++ branches/11/res/res_monitor.c Sat Dec  6 12:15:20 2014
@@ -388,6 +388,8 @@
                } else
                        monitor->write_stream = NULL;
 
+               ast_channel_insmpl_set(chan, 0);
+               ast_channel_outsmpl_set(chan, 0);
                ast_channel_monitor_set(chan, monitor);
                ast_monitor_set_state(chan, AST_MONITOR_RUNNING);
                /* so we know this call has been monitored in case we need to 
bill for it or something */


-- 
_____________________________________________________________________
-- Bandwidth and Colocation Provided by http://www.api-digital.com --

svn-commits mailing list
To UNSUBSCRIBE or update options visit:
   http://lists.digium.com/mailman/listinfo/svn-commits