> It seems to me the set.config procedure does actually not work and it > is unable to correctly set the right values.
Config method working fine! (But you are not checking error code after Config call, so you not know when it fails!) And it failing, because you are setting invalid set of parameters. (Or you are really want 1.5 stopbits?) See for manual or comments in sources. Best is use predefined constants for stopbit configuration... -- Lukas Gebauer. E-mail: [EMAIL PROTECTED] http://synapse.ararat.cz/ - Ararat Synapse - TCP/IP Lib. ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ synalist-public mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/synalist-public