I'm trying to use SynCE to connect more than a dozen WM devices at
once. I have got it to work for multiple devices as long as they're
all in PPP mode but some of the devices can only be set in RNDIS mode
(namely the Blackjack 1 and Blackjack 2). For these devices only the
first one I'm connecting will create a new network interface (eth1)
and any other RNDIS phone I plug in will not create a new interface
but the dmesg output is fine (ie the same as the first device)

So I thought it might be an IP collision so I edited
HKEY_LOCAL_MACHINE\Comm\DTPT\DTPTCLI_ADDR and DTPTSER_ADDR and the
device now connects using the new IP, but the first device is still
the only one creating an interface.

So does anyone have any ideas of what might be preventing the second
interfaces from appearing?

(I also tried setting
HKEY_LOCAL_MACHINE\Drivers\USB\FunctionDrivers\DefaultClientDriver to
Serial_Class instead of RNDIS on the devices that wouldn't let me
disabled advanced networking through the GUI, but no interfaces were
made in that mode either)

dmesg even says [11839.205688] eth2: register 'rndis_host' at
usb-0000:00:1a.1-1, RNDIS device, 80:00:60:0f:e8:00

eth2 even though no eth2 exists afterward

Any thoughts on what unique value I can change so that the second (and
third) devices are detected?  All of them use the HWaddr of
80:00:60:0f:e8:00.

Thanks!

-David Richardson

------------------------------------------------------------------------------
Register Now for Creativity and Technology (CaT), June 3rd, NYC. CaT
is a gathering of tech-side developers & brand creativity professionals. Meet
the minds behind Google Creative Lab, Visual Complexity, Processing, & 
iPhoneDevCamp asthey present alongside digital heavyweights like Barbarian
Group, R/GA, & Big Spaceship. http://www.creativitycat.com 
_______________________________________________
SynCE-Devel mailing list
SynCE-Devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/synce-devel

Reply via email to