hello, I was troubleshooting a failed drive in the array when all of a sudden 
after a reboot I no longer see any array drives from format command and dmesg 
and /var/adm/messages show these messages every few seconds:

Jul 30 17:33:26 whitedragon scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],2000/SUNW,[EMAIL PROTECTED] (ifp0):
Jul 30 17:33:26 whitedragon     LIP reset occurred; cause f7f7
Jul 30 17:33:45 whitedragon scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],2000/SUNW,[EMAIL PROTECTED] (ifp0):
Jul 30 17:33:45 whitedragon     Loop is down: finishing off loop reconfig
Jul 30 17:33:45 whitedragon scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],2000/SUNW,[EMAIL PROTECTED] (ifp0):
Jul 30 17:33:45 whitedragon     Loop reconfigure done, LIP
Jul 30 17:33:52 whitedragon scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],2000/SUNW,[EMAIL PROTECTED] (ifp0):
Jul 30 17:33:52 whitedragon     LIP occurred; cause f7f7
Jul 30 17:33:52 whitedragon scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],2000/SUNW,[EMAIL PROTECTED] (ifp0):
Jul 30 17:33:52 whitedragon     LIP reset occurred; cause f7f7
Jul 30 17:34:13 whitedragon scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],2000/SUNW,[EMAIL PROTECTED] (ifp0):
Jul 30 17:34:13 whitedragon     LIP occurred; cause f7f7
Jul 30 17:34:13 whitedragon scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],2000/SUNW,[EMAIL PROTECTED] (ifp0):
Jul 30 17:34:13 whitedragon     LIP reset occurred; cause f7f7

>From OK prompt I tried:  
probe-scsi-all 
and received this message:

ERROR: Timed-out waiting for the firmware Ready state
Current firmware state Configuration Wait
ERROR: Unable to get current loop ID (0001)

cfgadm -al gives me this:

# cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
ac0:bank0                      memory       connected    configured   ok
ac0:bank1                      memory       connected    configured   ok
ac1:bank0                      memory       connected    configured   ok
ac1:bank1                      memory       connected    configured   ok
c0                             scsi-bus     connected    configured   unknown
c0::dsk/c0t6d0                 CD-ROM       connected    configured   unknown
c0::dsk/c0t10d0                disk         connected    configured   unknown
c0::dsk/c0t11d0                disk         connected    configured   unknown
c2                             scsi-bus     connected    unconfigured unknown
c3                             fc           connected    unconfigured unknown
sysctrl0:slot0                 cpu/mem      connected    configured   ok
sysctrl0:slot1                 dual-pci     connected    configured   ok
sysctrl0:slot2                 cpu/mem      connected    configured   ok
sysctrl0:slot3                 disk         disconnected unconfigured unknown
sysctrl0:slot4                 unknown      empty        unconfigured unusable
sysctrl0:slot5                 dual-pci     connected    configured   ok
sysctrl0:slot6                 unknown      empty        unconfigured unusable
sysctrl0:slot7                 unknown      empty        unconfigured unknown



Can someone please help me understand what is going on here?
 
 
This message posted from opensolaris.org
_______________________________________________
sysadmin-discuss mailing list
[email protected]
http://mail.opensolaris.org/mailman/listinfo/sysadmin-discuss

Reply via email to