yup, username works. a soon as I launch meditech and start typing (manually typing no scripts typing) I get a few letters typed and then meditech wipes them out and have to type it all over again.
If I'm not running BWS... no wipe away... I can type as soon as I launch meditech On Mon, Sep 23, 2013 at 2:23 PM, <[email protected]> wrote: > Is the User name correct and active in the Universe?**** > > ** ** > > ** ** > > *From:* [email protected] [mailto:[email protected]] > *Sent:* Monday, September 23, 2013 11:21 > *To:* [email protected] > *Subject:* [talkbws] Meditech 5.65 login issue**** > > ** ** > > Hi, I have a script that run when Meditech is launched, I have an issue > that the username wipeout as you are typing it in. The script only runs > when EMR is launched, so I don't see anything there being an issue.**** > > ** ** > > Side Note: I inherited the script too.**** > > ** ** > > Here's what is in the script for connecting to Meditech. > **** > > ** ** > > Function connectToMediTech() As Boolean**** > > **** > > Const ROUTINE_NAME As String = "MediTechEMRUtils.connectToMediTech"*** > * > > **** > > Dim returnValue As Boolean**** > > Dim ProcessID As Long**** > > **** > > On Error GoTo handler:**** > > **** > > returnValue = False ' until proven otherwise.**** > > **** > > Dim mediTechProcessName As String**** > > mediTechProcessName = GetMediTechExeName**** > > **** > > If IsProcessRunning(mediTechProcessName) Then**** > > Shell_ GetMediTechFocusPath & " MeditechStream"**** > > Call BostonWorkStation70.Connect("MeditechStream", stStream)**** > > Key "@_FORCETOTOPON"**** > > returnValue = True**** > > End If**** > > **** > > connectToMediTech = returnValue**** > > **** > > Exit Function**** > > **** > > handler:**** > > ** ** > > Call logger.LogError(Err, ROUTINE_NAME)**** > > Call Err.Raise(Err.Number, , ROUTINE_NAME & ": " & Err.Description)*** > * > > **** > > End Function**** > > ** ** > > ** ** > > --- To post a message to this list, send mail to: [email protected] You > are currently subscribed as: [email protected] Unsubscribe in the > customer center on our website: > http://www.bostonsoftwaresystems.com/Customers/ListServe.aspx **** > > --- To post a message to this list, send mail to: [email protected] You > are currently subscribed as: [email protected] Unsubscribe in > the customer center on our website: > http://www.bostonsoftwaresystems.com/Customers/ListServe.aspx > > This message and accompanying documents are covered by the Electronic > Communications Privacy Act and the Health Insurance Portability and > Accountability Act. This message is intended only for the use of the > individual or entity to which it is addressed and may contain information > that is confidential and/or privileged. If the reader of this message is > not the intended recipient, you are hereby notified that any dissemination, > distribution or copying of this communication is strictly prohibited. If > you have received this communication in error, please notify the sender > immediately by e-mail, and delete the original message. Thank you. -- *Kind Regards,* * * *Tom Aitas* *HL7 Integration Analyst* *PatientOrderSets.com* Direct: 416-479-9536 Toll Free: 1-877-781-0707 x 410 Fax: 416-977-1955 --- To post a message to this list, send mail to: [email protected] You are currently subscribed as: [email protected] Unsubscribe in the customer center on our website: http://www.bostonsoftwaresystems.com/Customers/ListServe.aspx