I downloaded WorkStation and WebStation from the Boston website yesterday. I had installed WebStation yesterday after I installed WorkStation. This morning I received the new activation key and WorkStation said that it was accepted. I reinstalled WebStation and it doesn't seem to make a difference. If I comment out the one line "C.WBDisconnect" the program will compile (Yes I'm using VB6) but it crashes when I try to run it. I see the WebStation program and the correct website in the WebStation window, then I get a message from XP that it is shutting down WebStation.

Rich McNeil wrote:

Neil,

It's likely that you'll need to install Boston WebStation.  It's available
on our website.  I'm assuming that you're still using VB6.  The WebStation
will work in our new WorStation VBA environment, but some modifications are
necessary (the soon to be released version 7 will include the WebStation).

If I'm off base here, give us a call and I'll Webex in to check it out.

Rich McNeil
Boston Software Systems
866 653 5105
www.bostonworkstation.com


-----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Neil Carman Sent: Friday, February 13, 2004 3:08 PM To: Boston WorkStation Subject: [Talk] Method or Data Member not found

I recently upgraded my development PC to a new Win XP machine.  I also
installed Boston WorkStation 6.5.  I had a Boston WebStation program that
was working fine but when I tried to recompile it, I first got the message
that the reference to Boston WebStation was missing.  I found a reference in
my available references that was a slightly different spelling of Boston
WebStation and added that.  When I tried to compile again I received the
message

Method or data member not found

The subroutine was in a standard "script.bas" file and the error was
referring to C.WBDisconnect

Sub DisConnect()
   On Error Resume Next
   C.WBDisconnect
   Set C = Nothing
   Set Z = Nothing
End Sub

Does anyone have any suggestions about this?  I had gotten the "script.bas"
module from a previous version of Boston WebStation.  Do I need a new bas
module for the upgraded version of Boston WebStation? Is C.WBDisconnect no
longer a valid method in the new version?

--
Neil Carman
Director Technical Development
Manigault & Associates LLC

http://www.m-allc.com
Work: (805) 680-5601
Fax:  (714) 968-5632








-- Neil Carman Director Technical Development Manigault & Associates LLC

http://www.m-allc.com
Work: (805) 680-5601
Fax:  (714) 968-5632



Reply via email to