Greetings,

BWS has to launch Meditech in order to connect to it. 

A "trick" to allow BWS to connect at will to a running session is to have
the Meditech icon launch a "one line" script that just launches Meditech.

Here's what you need to do for 3.x
Connect "path to t.exe (optional)", stMeditech, "MyStream"
Then your script can connect at will using:
Connect "MyStream", stStream

Client Server is identical to the above except it stMeditechCS and the path
is to Vmagic.exe (or the new client exe whose name escapes me at the moment)

For NUI the process is to use:
Shell_ "c:\Bss70\MeditechNUIServer.exe Mystream c:\...t.exe"
The myStream and path to t.exe are optional
The default stream name will be MeditechNUI
So you could connect at will later using:
Connect "MeditechNUI", stStream

I've done things where I've supported allowing multiple instances of
Meditech to be launched / connected to in this manner but don't want to make
this email longer than it needs to be right now - let me know if you want
this information.

For your scripts that connect to these running instances, you want to test
to see if the connection (stream name) was available using Active - either
in command form:

If not Active("MyStream") then
        Connect "",stMeditech,"MyStream"
End if

Or have a rule testing against the Not Active condition.

Hope this helps!
Regards,
Thom



Thom C. Blackwell
Product Manager
Boston Software Systems
(866) 653-5105 ex 807
www.bossoft.com

LEGAL NOTICE Unless expressly stated otherwise, this message is confidential
and may be privileged. It is intended for the addressee(s) only. Access to
this E-mail by anyone else is unauthorized. If you are not an addressee, any
disclosure or copying of the contents of this E-mail or any action taken (or
not taken) in reliance on it is unauthorized and may be unlawful. If you are
not an addressee, please inform the sender immediately, then delete this
message and empty from your trash.

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Zimmerman, Scott
Sent: Monday, October 09, 2006 11:30 AM
To: BostonWorkstation Talk (E-mail)
Subject: [Talk] UMass Meditech Magic stream issue


Hello all,
Does anyone know of a way to connect to an already active Meditech session
in order to begin using bostonworkstation to execute following functions?
Whenever I use the "Connect" code it always wants to open a new session.
Finally, I guess it would need to also "disconnect" when function is
complete.

thank you,

Scott Zimmerman
Laboratory Information Systems Analyst
UMass Memorial Medical Center
Department of Hospital Labs
Office:  508-334-7237
Page:  508-426-2178 (mailto:[EMAIL PROTECTED])


<html><body><i>The information transmitted is intended only for the person
or entity to which it is addressed and may contain confidential and/or
privileged material.  Any review, transmission, re-transmission,
dissemination or other use of, or taking of any action in reliance upon this
information by persons or entities other than the intended recipient is
prohibited.  If you received this in error, please contact the sender and
delete the material from any computer.</i></body></html>




Reply via email to