On Tue, Aug 18, 2015 at 06:50:00AM -0500, o1bigtenor wrote: > On Mon, Aug 17, 2015 at 4:38 PM, Lennart Sorensen < > [email protected]> wrote: > > > On Sun, Aug 16, 2015 at 10:33:49PM -0500, o1bigtenor wrote: > > > Greetings > > > > > > Managed to buy a Dell poweredge 2950II server. > > > > > > What an odyssey to set up the bios!!! > > > > > > I have 2 drives I got with the machine - - - they were part of a Raid 5 > > > array. > > > Now there are only 2 drives (will never by a raid 5 array by definition) > > > and I need some way of formatting them so that I can turn them into a > > Raid > > > 1 array. (Its all hardware raid on this box.) > > > > > > Anyone with any idea on how to do that to scsi drives when the controller > > > won't let me change their settings and I have no other pox to put them > > in. > > > (Connector is a wee bit different than for SATA!)
That would be SAS. SAS controllers can run SATA disks, but no the other way around. > > Certainly some raid controllers have an initialize option you can apply > > to disks to clean them so they can be reused in a new raid. > > > > No idea which raid controller model you are dealing with. > > > > Its a Perc 5/i if that helps. Well here is a handy video: https://www.youtube.com/watch?v=D5lGWdvJyS4 It seems you hit control-r to enter the raid setup when prompted, then in there there is a PD management tab (PD = physical disk I suspect) Looks like control-n is how to change tabs. I found a page that says if you see 'foreign' config present, then you can hit F2 on the controller on the VD management page and ask it to clear that. -- Len Sorensen --- Talk Mailing List [email protected] http://gtalug.org/mailman/listinfo/talk