dear all
aku coba masukin ke mrtg.cfg , ko ada error seperti ini :
[EMAIL PROTECTED] libpcap-0.8.1]# /usr/local/mrtg/bin/cfgmaker
[EMAIL PROTECTED] >> /home/sonjaya/www/noc/mrtg/mrtg.cfg
--base: Get Device Info on [EMAIL PROTECTED]:
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.1.9.1.4.9)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753368
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
--base: Vendor Id:
--base: Populating confcache
--snpo: Skipping ifName scanning because [EMAIL PROTECTED]: does not seem
to support it
--snpo: Skipping ifDescr scanning because [EMAIL PROTECTED]: does not
seem to support it
--snpo: Skipping ifType scanning because [EMAIL PROTECTED]: does not seem
to support it
--snpo: Skipping ipAdEntIfIndex scanning because [EMAIL PROTECTED]: does
not seem to support it
--snpo: Skipping ifPhysAddress scanning because [EMAIL PROTECTED]: does
not seem to support it
--base: Get Interface Info
--base: Walking ifIndex
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.1)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753362
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.1)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753362
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
no response received
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753362
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMPWALK Problem for 1.3.6.1.2.1.2.2.1.1 on [EMAIL PROTECTED]::::::v4only
at /usr/local/mrtg/bin/cfgmaker line 140
--base: Walking ifType
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.3)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753361
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.3)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753361
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
no response received
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753361
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMPWALK Problem for 1.3.6.1.2.1.2.2.1.3 on [EMAIL PROTECTED]::::::v4only
at /usr/local/mrtg/bin/cfgmaker line 140
--base: Walking ifAdminStatus
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.7)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753360
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
no response received
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753360
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMPWALK Problem for 1.3.6.1.2.1.2.2.1.7 on [EMAIL PROTECTED]::::::v4only
at /usr/local/mrtg/bin/cfgmaker line 140
--base: Walking ifOperStatus
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.8)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753359
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.8)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753359
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
no response received
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753361
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMPWALK Problem for 1.3.6.1.2.1.2.2.1.3 on [EMAIL PROTECTED]::::::v4only
at /usr/local/mrtg/bin/cfgmaker line 140
--base: Walking ifAdminStatus
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.7)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753360
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
no response received
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753360
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMPWALK Problem for 1.3.6.1.2.1.2.2.1.7 on [EMAIL PROTECTED]::::::v4only
at /usr/local/mrtg/bin/cfgmaker line 140
--base: Walking ifOperStatus
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.8)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753359
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.8)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753359
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
no response received
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753359
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMPWALK Problem for 1.3.6.1.2.1.2.2.1.8 on [EMAIL PROTECTED]::::::v4only
at /usr/local/mrtg/bin/cfgmaker line 140
--base: Walking ifSpeed
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.5)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753358
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
Received SNMP response with error code
error status: noSuchName
index 1 (OID: 1.3.6.1.2.1.2.2.1.5)
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753358
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMP Error:
no response received
SNMPv1_Session (remote host: "172.18.9.10" [172.18.9.10].161)
community: "public"
request ID: -2128753358
PDU bufsize: 8000 bytes
timeout: 2s
retries: 5
backoff: 1)
at /usr/local/mrtg/bin/../lib/mrtg2/SNMP_util.pm line 621
SNMPWALK Problem for 1.3.6.1.2.1.2.2.1.5 on [EMAIL PROTECTED]::::::v4only
at /usr/local/mrtg/bin/cfgmaker line 167
nah kira kira apa yang salah yach , saya coba capture wirrelles bridge
engga masalah , trus switch yg manageable juga engga masalah .
thank's
--
Unsubscribe: kirim email kosong ke [EMAIL PROTECTED]
Arsip dan info di http://linux.or.id/milis.php
FAQ milis http://linux.or.id/faq.php