For those of you who run Novell and or Zenworks (ZCM), Window 7 and image
you need to do a couple of things to work with ZCM and then if you want to
have Windows 7 be able to activate properly then you need to do something
else too.

 

Windows 7 has to have sysprep run with the generalize feature for the
activation to work, even though you change the SID it doesn't let you
activate as Windows 7 has to have each machine be a completely different
machine for it to work.

 

Zenworks is easier, but if you follow all of the steps below after the image
process and sysprep it will make you put in a computer name and will
register in ZCM.

 

Zac unr -u user -p password    Will unregister the client with the server

Zac reg -u user -p password https://serverip      will register the client
with the server

Zac  fsg -d     Removes the client info from just the client, but does not
unregister from the server, but you can delete the workstation from the
server too

 

This works below to remove all of the previous GUID settings and gets the
machine ready for imaging.  Run sysprep at the end - Windows 7 it is in
C:\Windows\System32\sysprep and select generalize.  This also when the image
is done will have you put in a computer name and it will register with
Zenworks automatically.

 

- 1: Install a machine with the zen client (and or novell client)

- 2: Run regedit and delete the following entries:

HKLM\Software\Novell\Zenworks\Preagent\GUID entry

HKLM\Software\Novell\Zenworks\Remote Management\ALL machine name entries

- 3: Now stop all novell services on the workstation (should be 3-5)

- 4: Browse to c:\program files\Novell\Zenworks\Cache and delete the entire
ZMD directory

- 5: Browse to c:\program files\Novell\ZenWorks\Conf dir and 

delete the following files: Devicedata, deviceguid, GUID.txt 

rename the initial-web-service.bak to initial-web-service

(IF YOU DON'T DO THIS The machines WILL GET another SID, but DON'T GET
ANOTHER GUID AND DEVICEID. ) even if they are cleaned of preboot settings

- 6: Run c:\program files\Novell\Zenworks\Bin\Preboot\ziswin

- 7: Click Edit| Clear imagesafe data and save

- 8: Click no on the mark for just imaged question

- 9: Optional for Microsoft SUS server (see details below)

- 10: Run sysprep -mini -quiet -reseal. (Windows 7 has sysprep in
C:/windows/system32/sysprep/)

 

DON'T START THE MACHINE IN WINDOWS AGAIN, BUT TAKE AN IMAGE AT THIS POINT!

 

Dan

 

Daniel Zobel

Director of Technology

Heyworth CUSD#4

Direct Phone 309-473-2250

Grade School 309-473-2822

High School 309-473-2322

Unit Office 309-473-3727

 

_______________________________________________
Tech-geeks mailing list
Tech-geeks@tech-geeks.org
http://lists.illinicloud.org/cgi-bin/mailman/listinfo/tech-geeks