On Wed, Nov 28, 2012 at 08:28:10AM +0100, Alexander Hall wrote:
> Make sure new config is valid before SIGHUP'ing sshd, which would
> otherwise just kill it. Invalid configuration now gives:
>
> # pgrep sshd
> 18998
> # /etc/rc.d/sshd reload
> sshd(failed)
> # pgrep sshd
> 18998
>
> Pros: Less risk of accidentally killing sshd and locking yourself out.
> Cons: You may think that you have made changes that have not taken
> effect, and will still screw you after a reboot.
I don't understand what this means...
>
> I think the pros win anyway.
>
> OK?
I'm in favor of this. But please put a blank line after sourcing
/etc/rc.d/rc.subr for readability.
> /Alexander
>
> Index: rc.d/sshd
> ===================================================================
> RCS file: /data/openbsd/cvs/src/etc/rc.d/sshd,v
> retrieving revision 1.1
> diff -u -p -r1.1 sshd
> --- rc.d/sshd 6 Jul 2011 18:55:36 -0000 1.1
> +++ rc.d/sshd 28 Nov 2012 00:27:01 -0000
> @@ -6,4 +6,8 @@ daemon="/usr/sbin/sshd"
> . /etc/rc.d/rc.subr
> +rc_reload() {
> + ${daemon} ${daemon_flags} -t && pkill -HUP -f "^${pexp}"
> +}
> +
> rc_cmd $1
>
--
Antoine