I don't know about the HOT but Q601 and 602 need to be Sony parts. The same
thing happened to me with generic type replacements.
Bruce.

B&T Electronics
139 Margaret St
Sarnia Ontario
Canada
N7T 2Y3

----- Original Message ----- 
From: "Calvin Neal" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Tuesday, June 22, 2004 12:10 PM
Subject: [Techs] Sony TV model KV27TW77


> Set came in with shorted HOT(Q-591),Q-601,Q602
> shorted, and R-607 open.  I used NTE 2582 for Q-601
> and Q-602, and NTE 2636 for the HOT.  I let it run for
> about 5 minutes, and then checked the temperature of
> the HOT...which was running only slightly warm to the
> touch.  I stepped outside of the shop for a few
> minutes, and when I came back in....set was off.
> Q-601 and 602 were shorted and R-607 opened again.
> HOT checked fine.  Did I miss something here??? Do I
> need to use original Sony parts?  Thanks for any help
>
> Calvin Neal
> Orrington Electronics
> Orrington, Maine
>
>
>
> __________________________________
> Do you Yahoo!?
> Yahoo! Mail - 50x more storage than other providers!
> http://promotions.yahoo.com/new_mail
>
> _______________________________________________
> Tech Repair CD...order your just $49.00 plus shipping...One year of
updates free.
> www.intrepid-video.com www.tech-repair.net
> Techs mailing list
> [EMAIL PROTECTED]
> http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com
>



_______________________________________________
Tech Repair CD...order your just $49.00 plus shipping...One year of updates free.
www.intrepid-video.com www.tech-repair.net
Techs mailing list
[EMAIL PROTECTED]
http://intrepid-video.com/mailman/listinfo/techs_intrepid-video.com

Reply via email to