Same here, I have seen that happen before. I would say 2 or 3 out of 40 on a eNB will not come back within 30 mins and need a reboot. I did see a UE that did not connect for many hours that popped back online, I called the customer and there were not home to reboot it, so why it took hours I dont know.
Matt Carpenter On Fri, Nov 11, 2016 at 2:32 PM, Andreas Wiatowski <[email protected] > wrote: > I second that…I hope that Telrad has a new version soon that fixes it. > > > > Cheers, > > ______________________________ > > Andreas Wiatowski | CEO > > Silo Wireless Inc. > > Email [email protected] > > 19 Sage Court > > Brantford, Ontario N3R 7T4 (CANADA) > > Tel +1.519.449.5656 Extension-600|Fax +1.519.449.5536 |Toll Free > +1.866.727.4138 > > > > *From:* [email protected] [mailto:[email protected]] *On > Behalf Of *Shayne Lebrun > *Sent:* Friday, November 11, 2016 10:09 AM > *To:* [email protected] > *Subject:* [Telrad] Stuck UEs after ungraceful EPC loss > > > > Is anybody else still seeing the phenomena where, if the EPC goes away > ‘ungracefully,’ say by losing power, rather than being ‘request reset > reset’ed, that UEs often don’t reattach without a power cycle? > > > > We’ve seen it on every firmware version so far, including 105. > > _______________________________________________ > Telrad mailing list > [email protected] > http://lists.wispa.org/mailman/listinfo/telrad > > -- *Matthew Carpenter* *806-316-5071 office* *806-236-9558 cell*