Hi all

a) Using MTX I need a meter called in PMX 4/0/0/4. The first problem is
that MTX refuses the first zero although this would make sense, regarding
PMX's language. Well, this is not a real problem, since m8/2/0/4 fixes
this. But the second problem is that the third and fourth numbers do not
go through MTX. In the resulting PMX file I find in the preamble "8 2 8 2"
instead of the expected "8 2 0 4". Is this intended?

b) Apparently, MTX cannot handle the nice "rp" full bar rest provided by
PMX. This seems to mess up MTX's meter/length counting. In the above
mentioned meter I would like to use a \PAUSe. Well, "\PAUSe\ rb9 rb9" or
"rb9 \PAUSe\ rb9" are workarounds but both do not produce very nice output
since a full bar rest should appear centered within the bar. A construct
with \centerPAUSe\ on the other hand is also not a real solution as the
pice has 12 voices and many such rests. So I don't see a direct TeX macro
solution.

Does anyone have a suggestion?

regards
Bernhard