calibrate calibrate <quantity list> <zero error> [<scale>]
measured value = (read value â zero error) x scale in this ocasion: calibrate clino 90 -1 119: (119-90) x -1 = -29 m. On Dec 11, 2012, at 9:41 PM, cawa sorix <cawa.sorix at gmail.com> wrote: > Hi all, > > I had an issue today on data with Vulcain topofil data. > On Vulcain topofil the clino is from 0 to 180° and > 0 = +90 > 90 = 0 > 180 = -90 > > I didn't find anything on survex documentation about that. > Do you have any idea about the right setup for the survex line ? > > I have no idea what is the right word for the ?? > > Example : > units compass grad > units clino grad > data normal from to fromcount tocount compass ?? left right up down > 1-0 1-1 6762.0 6799.0 385.00 119.00 0.40 0.30 > 1.00 1.00 > 1-1 1-2 6799.0 6999.0 235.00 106.00 0.40 0.40 > 0.90 0.20 > > C.S. > _______________________________________________ > Therion mailing list > Therion at speleo.sk > http://mailman.speleo.sk/mailman/listinfo/therion -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://mailman.speleo.sk/pipermail/therion/attachments/20121211/f87d9f47/attachment.html>
