depthchange did the trick, you're all amazing :-) I did want to use LRUD data by the way Martin, but thanks for considering it in your answer!
I also wanted to take altitude change into consideration, but after running into substantial dry passage after pushing a deep(ish) siphon, there isn't always a clinometer at hand... Thanks again! Anton > Gesendet: Dienstag, 14. Juli 2020 um 20:59 Uhr > Von: "Martin Sluka via Therion" <[email protected]> > An: "List for Therion users" <[email protected]> > Cc: "Martin Sluka" <[email protected]> > Betreff: Re: [Therion] Survey without clino > > And > > data dimensions station left right up down > > h1 2.00 0.00 8.00 0.00 > ... > > Martin > > > > 14. 7. 2020 v 20:51, Tarquin Wilton-Jones via Therion <[email protected]>: > > > > Hi Anton, > > > >> the following line just goes down where it should be going up: > >> > >> data diving from to tape compass fromdepth todepth left right up down > > > > Just realised what your confusion is. "left" "right" "up" and "down" > > have nothing to do with the station-to-station data. They are for > > passage dimensions; the distance from the station to the walls, ceiling > > and floor. You almost certainly didn't need to use those at all. > > > > You probably wanted this: > > > > data cylpolar from to tape compass depthchange > > r112 h1 7.00 10.00 8.00 > > > > Note the spelling. There is a typo in the Survex docs. > > > > Tarquin > > _______________________________________________ > > Therion mailing list > > [email protected] > > https://mailman.speleo.sk/listinfo/therion > > _______________________________________________ > Therion mailing list > [email protected] > https://mailman.speleo.sk/listinfo/therion > _______________________________________________ Therion mailing list [email protected] https://mailman.speleo.sk/listinfo/therion