depthchange did the trick, you're all amazing :-)

I did want to use LRUD data by the way Martin, but thanks for considering it in 
your answer!

I also wanted to take altitude change into consideration, but after running 
into substantial dry passage after pushing a deep(ish) siphon, there isn't 
always a clinometer at hand...

Thanks again!

Anton

> Gesendet: Dienstag, 14. Juli 2020 um 20:59 Uhr
> Von: "Martin Sluka via Therion" <[email protected]>
> An: "List for Therion users" <[email protected]>
> Cc: "Martin Sluka" <[email protected]>
> Betreff: Re: [Therion] Survey without clino
>
> And
>
> data dimensions station left right up down
>
>  h1   2.00   0.00   8.00   0.00
> ...
>
> Martin
>
>
> > 14. 7. 2020 v 20:51, Tarquin Wilton-Jones via Therion <[email protected]>:
> >
> > Hi Anton,
> >
> >> the following line just goes down where it should be going up:
> >>
> >>    data diving from to tape compass fromdepth todepth left right up down
> >
> > Just realised what your confusion is. "left" "right" "up" and "down"
> > have nothing to do with the station-to-station data. They are for
> > passage dimensions; the distance from the station to the walls, ceiling
> > and floor. You almost certainly didn't need to use those at all.
> >
> > You probably wanted this:
> >
> > data cylpolar from to tape compass depthchange
> > r112    h1   7.00    10.00   8.00
> >
> > Note the spelling. There is a typo in the Survex docs.
> >
> > Tarquin
> > _______________________________________________
> > Therion mailing list
> > [email protected]
> > https://mailman.speleo.sk/listinfo/therion
>
> _______________________________________________
> Therion mailing list
> [email protected]
> https://mailman.speleo.sk/listinfo/therion
>
_______________________________________________
Therion mailing list
[email protected]
https://mailman.speleo.sk/listinfo/therion

Reply via email to