From: Bruce Griffiths <[email protected]>
Subject: Re: [time-nuts] Advice on 10 MHz isolation/distribution
Its easy to calculate a lower bound to the amplifier phase noise floor
from the signal level at the output and the amplifier output noise due
to feedback resistors together with the amplifier input voltage and
current noise.
The actual phase noise floor may be a few dB higher.
Bruce
Yes, it is easy to calculate.
Clay