From: Bruce Griffiths <[email protected]>
Subject: Re: [time-nuts] Advice on 10 MHz isolation/distribution

Its easy to calculate a lower bound to the amplifier phase noise floor 
from the signal level at the output and the amplifier output noise due 
to feedback resistors together with the amplifier input voltage and 
current noise.
The actual phase noise floor  may be a few dB higher.

Bruce

Yes, it is easy to calculate.

Clay


      