I have two Thunderbolts that I'm monitoring with Lady Heather. The temperature on the older unit (MFG 2/26/2004) seems to track the environment. The newer one (MFG 11-24-2004) shows 44.750000 °C and only changes in increments of exactly 1°.

Sounds like the newer one has the newer temperature sender chip (DS1620). Briefly, the chip manufacturer changed the innards and the high-resolution display feature. Trimble did not update the Tbolt, but continued to use the newer version of the chip. IIRC, chip revisions prior to E work properly in the Tbolt, while Rev. E (and later, if such exist) do not. The cure is to replace the IC with an older revision chip.

The archive has lots of information on this.

Best regards,

Charles











_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to