On Mon, 25 Mar 2013 14:03:23 -0400
David McGaw <[email protected]> wrote:
> Actually, most modern FFs are hardened against metastability so often a
> single synchronizer will do especially if it is feeding a synchronous
> circuit.
I would not count on that. Most 74xx that hobbyists use are from
the HC and HCT families. These have been designed in the 70s (IIRC)
and i very much doubt that any of the manufacturers changed anything
in their design since then.
Attila Kinali
--
The people on 4chan are like brilliant psychologists
who also happen to be insane and gross.
-- unknown