It isnt going to help I guess but WB transformers for 50ohm are usually
designed with a reactance of 150 ohms (3* termination) at the lowest
frequency required. It might give an idea where to look?.
Alan G3NYK
----- Original Message -----
From: <[email protected]>
To: <[email protected]>
Sent: Tuesday, January 28, 2014 6:26 PM
Subject: [time-nuts] Mini Circuits RF TX question
Hi,
Does anyone know where to find the primary inductance value for Mini
Circuits RF Transformers?
I need to know so I can pick one to resonate with a particular capacitor
at 5Mhz.
Thanks,
Corby