On 09/02/14 06:37, Mark Sims wrote:
What was the timebase for your counter?   I suspect that it is off freq and the 
Rb is not actually making it above 10 MHz.  Inverting the Rb is causing a 2G 
shift in gravity to the Rb crystal probably shifting its freq enough to cause 
lock.                                        

This is what I have been thinking about, and adjusting the VCXO frequency should help.

It would be interesting to confirm the 2G shift before adjustment.

Cheers,
Magnus