On Fri, December 18, 2015 4:50 pm, Bruce Griffiths wrote: > On Friday, December 18, 2015 12:27:33 PM Charles Steinmetz wrote: >> It is perfectly possible to ground coax connector bodies at RF >> without grounding them at power-line frequencies
> Something like an annular ring capacitor that insulates the BNC body from > the chassis whilst capacitively shorting it to the Chassis at RF ??. Yes, exactly what I was referring to previously when I mentioned the telecom solution to this problem. I have an Amp connector in my parts bin with this style of connection, but it doesn't have a full part number printed so I can't find the drawing. I believe this Amp patent from 1990 may refer to the method of assembling such a connector: http://www.google.com/patents/US5062811 -- Chris Caudle _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.