On Fri, December 18, 2015 4:50 pm, Bruce Griffiths wrote:
> On Friday, December 18, 2015 12:27:33 PM Charles Steinmetz wrote:
>> It is perfectly possible to ground coax connector bodies at RF
>> without grounding them at power-line frequencies

> Something like an annular ring capacitor that insulates the BNC body from
> the chassis whilst capacitively shorting it to the Chassis at RF ??.

Yes, exactly what I was referring to previously when I mentioned the
telecom solution to this problem.

I have an Amp connector in my parts bin with this style of connection, but
it doesn't have a full part number printed so I can't find the drawing.

I believe this Amp patent from 1990 may refer to the method of assembling
such a connector:
http://www.google.com/patents/US5062811

-- 
Chris Caudle


_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to