The Fury and other Jackson Labs GPSDOs can be put into manual holdover with the SYNChronization:HOLDover:INITiate command and taken out of holdover with the SYNChronization:HOLDover:RECovery:INITiate command.
The phase measurement from the sync:tint? query remains valid while in the manual holdover state, so that this phase data could be used to create a valid ADEV plot of the oscillator in holdover. Keith Keith On Thu, Mar 17, 2016 at 7:21 AM, Paul <[email protected]> wrote: > On Thu, Mar 17, 2016 at 10:00 AM, Tom Van Baak <[email protected]> wrote: > > > this feature should be in every GPSDO, but I think it's unique to the > > TBolt. > > > > I was under the impression that SYNChronization:HOLDover:INITiate did this > on the Fury. > Of course I'm used to embarrassing misapprehensions. > > -- > Paul > _______________________________________________ > time-nuts mailing list -- [email protected] > To unsubscribe, go to > https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. > _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.