Has anyone measured the details of the spread spectrum clocks used to help meet emission limits (like FCC Part 15)?

It seems, superficially, that they do this with some sort of deterministic process (like a linear feedback shift register), and so, one might be able to "back out" the (Pseudo)randomization to get better timing performance.


https://www.maximintegrated.com/en/app-notes/index.mvp/id/3503
seems to indicate that they use a up/down sweep approach.

https://www.maximintegrated.com/en/products/all-products/archive/MAX9492.html

https://www.idt.com/products/clocks-timing/application-specific-clocks/spread-spectrum-clocks/180-01-low-emi-clock-generator
"IDT's proprietary blend of analog and digital PLL technology"

https://www.idt.com/document/dst/idt5p50911-2-3-4-datasheet

seems to show a triangle wave frequency modulation


_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to 
http://lists.febo.com/mailman/listinfo/time-nuts_lists.febo.com
and follow the instructions there.

Reply via email to