The 30 dBc refers to the signal level reported by the Ublox. If the Ublox falls below around 30, the Truetime will be reporting -196 dBW. That seems to be the cutoff threshold for its idea of a "good" signal... it does not have a user settable signal level mask My conversion formula works very well over the full range of usable signals and matches what the Ublox is reporting within 1 dB.
------------------ > When you refer to "30 dBc", what is that? Is it the eb/n0 value? If so, with the XLi's behavior as you report it, your scheme would fail over most of the useful signal range. _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to http://lists.febo.com/mailman/listinfo/time-nuts_lists.febo.com and follow the instructions there.