Hello everyone,

I’ve resurrected an old and no longer supported implementation of PTP for the 
STM32 series of 32-bit microcontrollers.

In a nutshell: the ethernet MAC on these micros has hardware support for packet 
time stamping and fine-grained adjustment of a free running timer. ST Micro had 
released a port of the ptpv2 client/server which took advantage of this 
hardware using ptpd-2.0.0, but it’s been lost to the sands of time. I’ve 
figured out a similar port and it’s working pretty good.

The end application I’m working toward is a closed (no availability of internet 
or gps time) network where multiple devices are working together to measure 
position and orientation of objects in an environment with carefully 
synchronized LED flashes and camera exposures. Absolute time is unimportant, 
but everyone in the closed network agreeing on what time it is is very 
important, down to single-digit microseconds.

I have a pair of STM32F756 development boards syncing to a ptpd server running 
on Linux. Using the hardware, timer-based (no interrupts or software 
involvement) PPS output of the STM32s and a logic analyzer I can see that the 
two STM32 dev boards wander in and out of sync with each other. The absolute 
difference between the rising edges of the PPS signals ranges from a few 
hundred nanoseconds to about 40-50us over the span of about 20-30 minutes.

The test system has a single (non-1588-aware) network switch, but the final 
implementation will have a master with multiple network interfaces directly 
connecting to each slave. The logging output of the STM32s shows that the 
second-to-second offset error of a slave is in the neighbourhood of +/-1500ns, 
and the long-term drift stabilizes out around 1200-1500pps.

I’m looking to close the range of the short-term sync and try to hold the 
slaves to within a half dozen microseconds of each other if possible. Now the 
master clock is just a free-running clock on the PC (no GPS or NTP discipline) 
but the absolute time is unimportant for me; what is important is very tight 
sync between the slaves over the short (second-to-second) term.

I have some hardware coming in which will help me visualize how jittery the 
master clock is, as I suspect some of this “slop” in sync comes from the master 
clock jittering and the measurement of the master clock by one slave not being 
the same as the other slave, causing the timing loops to diverge.

My newbie questions revolve around the short term sync error. Will an 
undisciplined master clock aggravate the ability for multiple slaves to stay 
synchronized relative to each other? What if I used a 10MHz OCXO and divider to 
provide a PPS signal to the PC, lying to it that this is a GPS PPS output and 
disciplining the master clock that way? It’s my understanding that an OXCO 
short-term error is very small, and the GPSDOs take advantage of this attribute 
while using the GPS long-term stability to keep the time correct.

The other newbie question is regarding adjusting the PI loop in the pop 
codebase on the STM32 slaves; is there any value in trying to adjust the loop 
coefficients to favour shorter term stability? I’m leery to do this, as I am 
fully aware of my newbieness and that the coefficients are there after a LOT of 
hard work to get them to optimal values.

Thanks,