On Wed, Nov 12, 2014 at 02:51:05PM -0500, Alexandre Beaulieu wrote: > I'm sometimes getting a failure of connecting 2 nodes when Tinc is started > and configured in a LAN. In the logs, there are some unexpected dropped > packets with very high or negative seq. I can reproduce this issue ~2% of > the time. [...] > 2014-11-12 18:56:41 tinc.ccvpn[1879]: Packet from node5 (10.60.19.106 port > 655) is 1898092539 seqs in the future, dropped (1) > 2014-11-12 19:00:53 tinc.ccvpn[1879]: Packet from node5 (10.60.19.106 port > 655) is -1038452044 seqs in the future, dropped (2) > 2014-11-12 19:01:29 tinc.ccvpn[1879]: Packet from node5 (10.60.19.106 port > 655) is -2035506251 seqs in the future, dropped (3) > 2014-11-12 19:05:07 tinc.ccvpn[1879]: Packet from node5 (10.60.19.106 port > 655) is 1665101896 seqs in the future, dropped (4)
Hm, this should not happen of course. Can you tell me if you have
Cipher, Compression, Digest, and/or MACLength set in any of your
configuration files?
--
Met vriendelijke groet / with kind regards,
Guus Sliepen <[email protected]>
signature.asc
Description: Digital signature
_______________________________________________ tinc mailing list [email protected] http://www.tinc-vpn.org/cgi-bin/mailman/listinfo/tinc