Hello,
take a look at micm.nc
There you can set the samplerate:
call HPLADC.setSamplingRate(rate);
If you want to change the samplerate in your application, you can change e.g. micm and mic.c and implement a call for that.
You can change the samplerate from 0 to 7. In ADC.h you will find a enum which defines values for the sampling rate.
Regards,
Patrick
Abhishek <[EMAIL PROTECTED]> wrote:
Can we change the sampling interval rate at which the mica2 motes trigger the sensor(MTS300) to sample the values.
How low will we go? Check out Yahoo! MessengerÂ’s low PC-to-Phone call rates._______________________________________________