Could be a bug in the radio stack. Note that only one of two motes stops...
-Joe On 7/23/06, Philip Levis <[EMAIL PROTECTED]> wrote:
On Jul 22, 2006, at 6:31 AM, [EMAIL PROTECTED] wrote: > Hi, > > I've implemented BlinkToRadio application on telosb with tinyos 2.0. > Two telosb motes send packets to each other using BlinkToRadio > application. > Packets are sent in event Timer.fired() in BlinkToRadio application. > I found something wrong in telosb operation. > If TIMER_PERIOD_MILLI(packet generation interval)is set to 1(ms), > event > Timer.fired() of one of two motes is not signalled anymore after > several > seconds. As a result, only one mote can send packets. > If TIMER_PERIOD_MILLI is set to 2(ms), this situation seldom occures. > Have you ever seen this situation? This sounds like a bug in the MSP430 timer stack. Cory, have you encountered this? Phil _______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
_______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help