Hi, TEP 113 was last modified on 2006-06-14, but my tinyos July version works. Only after I updated from the lastest develop branch version, Java program does not communicate with motes via serial port.
On 10/23/06, Philip Levis <[EMAIL PROTECTED]> wrote:
On Oct 22, 2006, at 8:23 PM, Tie Luo wrote:
> After update the whole tinyos 2.x in October, using the develop
> branch, the apps/BaseStation does not work. In particular, using a
> Java program to open and write a message to the BaseStation via
> serial port will return error. While the same code can run on the
> previous version of tinyos.
>
> I have checked that BaseStation has not changed in the new version,
> so I think this problem is due to the change to serial comm codes.
The serial protocol has changed. Please read TEP 113.
Phil
--
Regards,
Tie
_______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help