On Oct 27, 2006, at 2:15 AM, John Thelen wrote:

Hi,

This summer there was some discussion about the current consumption of the MicaZ in tinyOS 2.x

Were these measurements the current consumption for the whole node circuitry or just the microcontroller?

Currently I am measuring in total 150 uA using HPLPowerManagement on a Mica2Dot using the 32 kHz clock.

Am I doing something wrong or do I need to upgrade to tinyOS 2.x to get the 5uA they measured on the MicaZ?


None of the measurements were on a mica2 dot. I don't know of any recent measurements for them under 2.x.

Phil