Try using the CC2420Packet.getRssi(.) command. -- Jonathan W. Hui [EMAIL PROTECTED] http://www.cs.berkeley.edu/~jwhui/
On 3/12/07, [EMAIL PROTECTED] <[EMAIL PROTECTED]> wrote:
I am using TinyOS 2.0 and the TelosB platform. I have a transmitting node and I am setting the tx power level on a per packet basis. For the receiving node, upon reception of a packet I am using the getPower() function in order to record the power levels of each incoming packet. My issue is that for each packet received I am just seeing zeros for the tx power of all incoming packets. Thanks. Dave _______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
_______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help