I am deciding on the motes to use for a soil sensor data collection network in the US. I like the range of 433 MHz MICA2 motes, but I am concerned about FCC regulation 15.231. My concern is that it limits the output power to the point that this frequency loses its value. Has anyone looked in-depth at this issue?

My understanding is that a data collection network such as mine cannot use the paragraph (a) power limits. Paragraph (a) systems seem to be limited to control-based systems, like a garage-door opener or a keyless entry system for a car.

In this case the data collection network must use paragraph (e) power limits. This means the EIRP of the transmitter must be no greater than -22 dBm peak, or no greater than, say, -5 to -10 dBm peak for a transmitter with a small duty cycle.

Thanks for any insight,
Ken Bannister