My apologies. After I did some calculation using the system's milliseconds
timer, I got five seconds interval from each mote.
Muhammad Azhar
Tue, 08 May 2007 19:14:00 -0700
Hi,
In the multihoposcilloscope implementation, the default interval is 1s.
From what I understand, this means that after every 1s, the
Timer.fired()
event would be called (assuming there is no change in version whatsoever).
Thus, since NREADINGS == 5, shouldn't I only get sensor readings only after
5 seconds from each mote? But I seem to get 5 sensor readings after 1s from
each mote. Can someone tell me why this happens?
Thanks in advance.
Regards,
Azhar
_______________________________________________
Tinyos-help mailing list
[email protected]
https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help