Hi, I use MTS310 to sample acceleration data. As the resolution of AD is 10 bit, the maximum data should be 0x3ff, but most of my data are around 0x7A80. I only revised the start time of ADXL202E from 17 ms to 3 ms in file 'AccelP.nc' as I changed two capacitors of ADXL202E from 0.1 uF to 0.01 uF. Is there might some code problem in files of MTS300, which were downloaded from CVS ( http://tinyos.cvs.sourceforge.net/tinyos/tinyos-2.x/tos/sensorboards/mts300/ )?
I list some sampled data as follows (in 16 bit format, high byte first): No. accelX accelY 3 68 129 0 122 128 3 72 128 192 122 128 3 74 129 64 122 64 The No. is not in sequence due to lost data when transmission. Where is problem? regards, Fangming
_______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help