I've had good expieriences just using MSP430GeneralIOC, etc.  As long as you
don't initialize the ADC, it won't act as one.  Check out the TelosPWM code
for an example of the general IO code.

Dan

On 6/4/07, Joan Cortes <[EMAIL PROTECTED]> wrote:

 Hello,

I'm trying to use in Tmotes the exclusive Digital I/O 0, 1, 2 and 3. I use
the command TOSH_MAKE_GIO0_OUTPUT(); in the StdControl.init() and later I
set or clr the pins in the application when appropriate. However I couldn't
use the GIO0 and GIO1, even when I make also outputs the ADC2 and ADC3, the
set and clr instruction don't work when pointing to GIO0 and GIO1. Therefore
I have been using ADC2 and ADC3 names to make it work. Any one knows how to
solve this problem?

Additionally, using the Pong application, I don't know why the destination
address always appears as 0 in the output RSSI,LQI files. I checked
application.nc and java code and everything seems right. Any idea?

Thanks, regards,

Joan