I've had good expieriences just using MSP430GeneralIOC, etc. As long as you don't initialize the ADC, it won't act as one. Check out the TelosPWM code for an example of the general IO code.
Dan On 6/4/07, Joan Cortes <[EMAIL PROTECTED]> wrote:
Hello, I'm trying to use in Tmotes the exclusive Digital I/O 0, 1, 2 and 3. I use the command TOSH_MAKE_GIO0_OUTPUT(); in the StdControl.init() and later I set or clr the pins in the application when appropriate. However I couldn't use the GIO0 and GIO1, even when I make also outputs the ADC2 and ADC3, the set and clr instruction don't work when pointing to GIO0 and GIO1. Therefore I have been using ADC2 and ADC3 names to make it work. Any one knows how to solve this problem? Additionally, using the Pong application, I don't know why the destination address always appears as 0 in the output RSSI,LQI files. I checked application.nc and java code and everything seems right. Any idea? Thanks, regards, Joan _______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
_______________________________________________ Tinyos-help mailing list [email protected] https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help